Monitoring Acid-Stimulation Treatments With Slickline Distributed-Temperature Sensing

Fig. 1—Principle of DTS temperature measurement.

Mechanical-diversion techniques can ensure acid injection into the various intervals of naturally fractured reservoirs. With these methods, surface pressure can be monitored to assess fluid-placement effectiveness for each zone treated, but uncertainty of the friction pressure in the pipe while pumping can result in an incorrect interpretation of fluid entry. A new technique using fiber-optic distributed-temperature-sensing (DTS) measurements offers a solution when bullheading by providing an indication of where the acid has been injected into the fractured reservoir.

Introduction

The variability of fracture density and aperture along with fluid conductivity poses challenges to the goal of achieving uniformity of acid distribution to all fractures in a well. The optimum technique would allow effective treatment of all fractures, be operationally efficient, and facilitate the determination of treatment effectiveness in real time.

Diversion of the treatment fluid helps ensure that the entire interval is stimulated effectively on the basis of design objectives. When diversion is not considered, there is a significant reduction in the ensurance of complete zonal coverage. In the past, the rule of thumb has been to recommend diversion when attempting matrix stimulation of more than 20 ft of zone.

This article, written by JPT Technology Editor Chris Carpenter, contains highlights of paper SPE 173640, “Monitoring Acid-Stimulation Treatments in Naturally Fractured Reservoirs With Slickline Distributed-Temperature Sensing,” by Stephen Grayson,SPE, Yosmar Gonzalez, Kevin England, SPE, Ryan Bidyk, and S. Farrell Pitts,SPE, Schlumberger, prepared for the 2015 SPE Coiled Tubing and Well Intervention Conference and Exhibition, The Woodlands, Texas, USA, 24–25 March. The paper has not been peer reviewed.
...
This article is reserved for SPE members and JPT subscribers.
If you would like to continue reading,
please Sign In, JOIN SPE or Subscribe to JPT

Monitoring Acid-Stimulation Treatments With Slickline Distributed-Temperature Sensing

01 June 2015

Volume: 67 | Issue: 6

STAY CONNECTED

Don't miss out on the latest technology delivered to your email weekly.  Sign up for the JPT newsletter.  If you are not logged in, you will receive a confirmation email that you will need to click on to confirm you want to receive the newsletter.